Stage 1: Reaching the site

  1. Choice of forthcoming workers for the sewer cleaning ought to consider the obligations they will be supposed to perform;
  2. The total risk implied in the cleaning movement ought to be made sense of obviously to the workers by the manager and ought to get their assent in composed before beginning cleaning exercises;

iii. A boss alongside sufficient apparatus and staff will arrive at the assigned site, ideally during the lean time of sewage stream in sewers;

  1. The manager will have the names, addresses, and crisis contact data of the staff associated with cleaning the sewers; and
  2. Proper defensive pinion wheels and wellbeing gadgets will be worn by the staff before starting crafted by cleaning the sewers.

Stage 2: Identification and detachment of the area

  1. Recognize the stretch to be cleaned and distinguish the sewer vents related to the stretch;
  2. Blockade the region where cleaning is to be done; and

iii. A bannerman will be positioned somewhere around 15 m in front of the site and ought to be apparent to approaching traffic for something like 150 m.

  1. Cones (like the one utilized by police) will be put out and about.

Stage 3: Verify the presence of any gases or different deterrents

  1. Ventilate the sewer line by opening 2-3 sewer vents on the two sides of the turning outstretch for something like 1 hour before the beginning of the work to guarantee break of poisonous gases; The specialist opening the sewer vent should not twist down into the opened sewer vent and this might cause his getting overwhelmed by Hydrogen Sulfide and, surprisingly, stumbling into the sewer vent.
  2. Use a gas screen, finder light, wet acetic acid derivation paper, or gas identifier covers to recognize any buildups of noxious gases like hydrogen sulfide, carbon monoxide, methane, and fuel fumes;

iii. Embed a long shaft with lead acetic acid derivation paper which will change over completely to a dark tone within the sight of hydrogen sulfide. The individual will do whatever it takes not to embed the paper by hand into the sewer vent.

  1. If gases are distinguished, stretch out holding up period to permit remaining gases to get away and to keep away from the opportunity of the blast, if. Rehash the methodology ordinarily for really looking at the getaway of poisonous gases;
  2. Before the beginning of the cleaning activity, workers will check for blocks that might defer the cleaning system; and
  3. Sham covers with welded texture or wire net will be utilized to cover the sewer vent, whenever required.

In any case, care ought to be taken to guarantee that the cover is sufficiently able to hold a man’s weight.

Stage 4: Removal of residue/wax – Mechanical Process

  1. Fitting machines, basically to the degree determined in this SOP are to be utilized to eliminate the residue/wax;
  2. The working methodology of these machines will be completely followed for cleaning; and

iii. The sewer vent cover will be shut firmly after cleaning.

Stage 5: Leaving the site

  1. All the hardware/apparatuses alongside the defensive pinion wheels and security gadgets that had any immediate contact with the sewage will be cleaned appropriately according to the cleaning technique determined by the maker;
  2. All the hardware, security gears, blockades, and so on will be taken out from the functioning region and the team will move to the base or the following site; and

iii. The whole situation will be observed and reported by the boss.